Stair Stringer Calculator

in

Type it the way you read the tape: 68 1/2, 5' 8 1/2", 68.5 or 174cm.

Type your total rise and the answer appears here.

Code check runs as you type
Where to measure
Where to measure total riseTotal risemeasure straight downlevel off the finished deckdeck or floorfinished ground or floor

Measure from the top of the finished upper floor or deck straight down to where the bottom step will land. Not level ground? Measure at the landing spot.

Drag, or use the arrow keys
AdjustTread, riser, lumber, nosing, units — the drawing updates as you go

Steps

Top of stair

Lumber

Stringer stock
Stringer spacing

Space (optional)

Show results in

Cut sheet

Your marks, cuts and shopping list fill in here.

Code check

  • Runs as soon as you enter a total rise.

Based on the IRC (2021 R311.7 / 2024 R318.7). Local codes vary — confirm with your building department before building.

Accurately cutting a stair stringer is essential for a safe, solid staircase. This stair stringer calculator provides exact framing square settings, board lengths, uncut throat depth, and the critical bottom riser drop cut. It also calculates stringer counts based on stair width and on-center framing spacing.

Enter your total rise above to see your customized stringer cut layout diagram, verified against IRC building code standards.


How to Use This Stair Stringer Calculator

  1. Enter your total rise: Measure vertical distance from finished upper floor down to the landing surface where stringers rest.
  2. Specify lumber and spacing: Under Adjust, select your stringer stock (2x12 recommended), tread thickness (1” for 5/4 decking, 1 1/2” for 2x lumber), and stair width.
  3. Follow the cut diagram: Review framing square settings, confirm your uncut throat is at least 5 inches, and print your cut sheet.

How Stair Stringers Are Calculated

A stair stringer is the diagonal timber carrying treads and risers. Calculating stringer layout requires four core mathematical steps:

1. Step Geometry and Framing Square Settings

Unit rise and unit run define the notch cutouts:

Risers = Total Rise ÷ 7.75, rounded up
Unit Rise = Total Rise ÷ Risers
Unit Run = Tread Depth

To mark the 2x12, clamp stair gauges on your framing square: unit rise on the tongue (short arm) and unit run on the blade (long arm).

2. Uncut Throat Depth (Structural Thickness)

Notches leave solid lumber beneath called the throat:

Altitude = (Unit Rise × Unit Run) ÷ (√(Unit Rise² + Unit Run²))
Throat = Board Width - Altitude

Building standards (including AWC DCA 6) require at least 5 inches of uncut throat. If throat depth drops below 5”, switch to wider stock or add support posts.

3. Bottom Riser Drop and Top Plumb Cut

4. Stringer Quantity and Spacing

Stringers required depend on stair width and tread material:

Stringers = (Stair Width) ÷ (On-Center Spacing), rounded up, + 1


Worked Example: 68 1/2” Rise with 2x12 Lumber

Calculation for a 68 1/2-inch total rise, 10 1/2-inch tread depth, framed from 2x12 lumber (11 1/4” actual width) for a 36-inch wide stair:


Residential Stair Code Limits (IRC R311.7 / R318.7)

Stringer cuts must comply with International Residential Code standards:

Requirement IRC Standard Practical Builder Tip
Max Riser 7 3/4” (197 mm) Keep risers equal; never exceed 7 3/4”
Min Tread 10” (254 mm) Measured nosing-to-nosing
Tread Nosing 3/4” to 1 1/4” Required when tread depth is under 11”
Riser/Tread Variation 3/8” max Largest step minus smallest step in flight
Min Headroom 6’ 8” (80”) Measured along pitch line of stairs
Min Width 36” Clear width between handrails or walls
Handrail 4+ risers Mounted 34” to 38” above nosings
Max Flight Rise 151” (12’ 7”) Taller flights require an intermediate landing
Min Landing 36” deep Must match or exceed staircase width

Based on the IRC (2021 R311.7 / 2024 R318.7). Local codes vary — confirm with your building department before building.


Frequently Asked Questions

Can I use a 2x10 for stair stringers?

A 2x10 leaves under 3 1/2 inches of uncut throat wood under 7 3/4” risers, violating the 5-inch structural requirement. Always use 2x12 dimensional lumber for cut stair stringers to prevent structural cracking.

How many stringers do I need for a 36-inch or 48-inch stair?

A 36-inch stair needs 3 stringers at 16” OC for 2x wood treads, or 4 stringers at 12” OC for composite decking. A 48-inch stair needs 4 stringers at 16” OC and 5 stringers at 12” OC.

How do I cut stringer notches without overcutting?

Use a circular saw along your layout lines, stopping the blade 1/4 inch before the inside corner. Finish the cut with a handsaw or jigsaw so you do not notch past the throat line and weaken the stringer.

What is the throat of a stringer and why does it matter?

The throat is the solid wood remaining between the notch inside corner and the bottom edge of the board. Residential building guidelines require at least 5 inches of throat to carry loads without splitting.

Why do I need to cut the bottom of the stringer?

You must trim the bottom of the stringer by the tread thickness. Adding the tread raises the first step, so without this cut, your bottom step would be too tall and violate building code.

What angle should stair stringers be cut at?

Residential stairs typically pitch between 34 and 37 degrees. An ideal climb angle is roughly 35 to 36 degrees, achieved with a 7 1/2” to 7 5/8” riser and a 10” to 10 1/2” run.